There is indication that at least some of the first-generation synthetic cannabinoids act at receptors other than cannabinoid CB1 and CB2 (Wiley et al., 2016), and a compound from the present study, 5F-MDMB-PINACA, was found to activate midbrain dopamine neurons, but not serotonin neurons (Asaoka et al., 2016
To evaluate whether the changes of coordinative functions by CNS damages were due to test substances, rota-rod test was performed using Rota-rod apparatus (Daejong, Seoul, Korea). The test apparatus for the locomotor activity test was designed to measure locomotor activity automatically using UV system (AM 1051, Benwick Electronics, Benwick, UK) when experimental animals moved in the chamber. In both tests, a group of mice were treated with negative control (vehicle, 1 mg/kg, i.p.), positive control (methamphetamine, 1 mg/kg, i.p.), or one of the three doses of test substances (0.1, 1, 5 mg/kg, i.p.) once every other day for 10 day
Figure 1.
Each training session lasted a maximum of 10 min, and the rats could earn up to 20 food pellets. Thirty minutes prior to the training sessions, rats received an injection of either vehicle or Δ9-THC and were subsequently placed in the behavior-testing chambers, where food (45-mg food pellets; Bio-Serve, Frenchtown, NJ) was available as a reinforcer for every ten responses (FR10) on a designated injection appropriate lever. A houselight was centered over the hopper close to the ceiling and was illuminated only when the levers were active. Each dose range included doses that were without effect to those producing at least 50% depression compared to vehicle control. Twenty-four male Sprague-Dawley rats were obtained from Envigo (Houston, TX). Male ND4 Swiss–Webster mice were obtained from Envigo (Houston, TX) at approximately 8 weeks of age and maintained in the University of North Texas Health Science Center (UNTHSC) animal facility for two weeks prior to testin
Moreover, a study conducted in the United Kingdom investigated components of e-liquids in 112 samples originating from prisoners, teenagers and test purchases of commercially available e-cigarettes taken between 2014 and 2021 . This is the first case report that describes the toxicological symptoms of vaping ADB-BUTINACA. Results of the DOA test (including testing for amphetamines, methamphetamines, barbiturates, benzodiazepines, cocaine, methadone, opioids, cannabis, tricyclic antidepressants) were available within 30 minutes and were all negative. We report a case of an involuntary intoxication of the SCRA ADB-BUTINACA after vaping. There are several pitfalls in the detection of SCRA in samples taken from the patient.
Data availabili
Moreover, genetic makeup, physiological conditions (age, gender and ethnicity), environmental influences (diet) and pathological factors (liver diseases, diabetes, and obesity) would further complicate the metabolism of drug
Figure 1.
These synthetic cannabinoids act directly at cannabinoid CB1 and CB2 receptors as does Δ9-tetrahydrocannabinol (Δ9-THC) found in marijuana, but have different chemical structures unrelated to Δ9-THC, different metabolism, and often greater toxicity (Fantegrossi et al., 2014). Discriminative stimulus effects were tested in rats trained to discriminate Δ9-tetrahydrocannabinol (3 mg/kg, 30-min pretreatment). 5F-MDMB-PINACA (also known as 5F-ADB, 5F-ADB-PINACA), MDMB-CHIMICA, MDMB-FUBINACA, ADB-FUBINACA, and AMB-FUBINACA (also known as FUB-AMB, MMB-FUBINACA) were tested for in vivo cannabinoid-like effects to assess their abuse liabilit
As synthetic cannabinoid receptor agonists (SCRA) are gaining popularity globally, clinicians have to understand that intoxication caused by vaping SCRA is not detected by commonly available tests. He confirmed that he had been vaping an electronic cigarette (e-cigarette) earlier that day just before the onset of his symptoms. Metabolic acidosis (1/3, 0/7) and respiratory acidosis (1/3, 0/7), All 10 patients recovered with supportive care, including intubation and ventilation for one case. In 3 cases ADB-BUTINACA was the only substance detected, while in seven other substances of misuse were also detected including other SCRA, opioids, benzodiazepines cocaine and pregabali
The same procedure was then applied to the mice once every day for 5 days. It was considered as coordination disturbance when mice fell from the test apparatus within 2 min. Mice that remained their position on the running apparatus at 10 rpm for at least 2 min were selected for further evaluation.
Table of Conten
High resolution mass spectrometry such as LC-QTOF-MS allows the detection and identification of a broad spectrum of recreational drugs, including new psychoactive substances. A point-of-care drugs of abuse (DOA) test was initially performed on the urine of the patient. He confirmed drinking 750 ml energy drink without any further consumption of food and using an e-cigarette from Gaziantep, Turkey 10 seconds before the onset of his first symptoms. He usually smokes a pack of cigarettes a day and sometimes smokes e-cigarettes. Combined with non-specific, transient symptoms, clinical recognition of SCRA intoxication is challenging .
Data availability
The intensity is plotted against the retention time for both chromatograms, demonstrating the 4f adb presence and elution profiles of nicotine and ADB-BUTINACA in the analysed vape liquid sample. LC-QTOF-MS Chromatograms of Nicotine (Top) and ADB-BUTINACA (Bottom) in the Vape Liquid used by the patient. The LC-QTOF-MS analysis showed that the e-liquid contained nicotine and ADB-BUTINACA (Fig. 1). Because the point-of-care DOA test is generally not able to detect synthetic recreational drug substances, the liquid of the e-cigarette was thereafter screened using liquid chromatography-quadrupole time-of-flight mass spectrometry (LC-QTOF-MS) on the Waters™ Xevo G3 QTOF MS system. After eating a light meal and drinking caffeinated sports drinks at the ER, the nausea complaints of the patient were reduced and the patient was discharged hom
To evaluate whether the changes of coordinative functions by CNS damages were due to test substances, rota-rod test was performed using Rota-rod apparatus (Daejong, Seoul, Korea). The test apparatus for the locomotor activity test was designed to measure locomotor activity automatically using UV system (AM 1051, Benwick Electronics, Benwick, UK) when experimental animals moved in the chamber. In both tests, a group of mice were treated with negative control (vehicle, 1 mg/kg, i.p.), positive control (methamphetamine, 1 mg/kg, i.p.), or one of the three doses of test substances (0.1, 1, 5 mg/kg, i.p.) once every other day for 10 day
Figure 1.
Each training session lasted a maximum of 10 min, and the rats could earn up to 20 food pellets. Thirty minutes prior to the training sessions, rats received an injection of either vehicle or Δ9-THC and were subsequently placed in the behavior-testing chambers, where food (45-mg food pellets; Bio-Serve, Frenchtown, NJ) was available as a reinforcer for every ten responses (FR10) on a designated injection appropriate lever. A houselight was centered over the hopper close to the ceiling and was illuminated only when the levers were active. Each dose range included doses that were without effect to those producing at least 50% depression compared to vehicle control. Twenty-four male Sprague-Dawley rats were obtained from Envigo (Houston, TX). Male ND4 Swiss–Webster mice were obtained from Envigo (Houston, TX) at approximately 8 weeks of age and maintained in the University of North Texas Health Science Center (UNTHSC) animal facility for two weeks prior to testin
Moreover, a study conducted in the United Kingdom investigated components of e-liquids in 112 samples originating from prisoners, teenagers and test purchases of commercially available e-cigarettes taken between 2014 and 2021 . This is the first case report that describes the toxicological symptoms of vaping ADB-BUTINACA. Results of the DOA test (including testing for amphetamines, methamphetamines, barbiturates, benzodiazepines, cocaine, methadone, opioids, cannabis, tricyclic antidepressants) were available within 30 minutes and were all negative. We report a case of an involuntary intoxication of the SCRA ADB-BUTINACA after vaping. There are several pitfalls in the detection of SCRA in samples taken from the patient.
Data availabili
Moreover, genetic makeup, physiological conditions (age, gender and ethnicity), environmental influences (diet) and pathological factors (liver diseases, diabetes, and obesity) would further complicate the metabolism of drug
Figure 1.
These synthetic cannabinoids act directly at cannabinoid CB1 and CB2 receptors as does Δ9-tetrahydrocannabinol (Δ9-THC) found in marijuana, but have different chemical structures unrelated to Δ9-THC, different metabolism, and often greater toxicity (Fantegrossi et al., 2014). Discriminative stimulus effects were tested in rats trained to discriminate Δ9-tetrahydrocannabinol (3 mg/kg, 30-min pretreatment). 5F-MDMB-PINACA (also known as 5F-ADB, 5F-ADB-PINACA), MDMB-CHIMICA, MDMB-FUBINACA, ADB-FUBINACA, and AMB-FUBINACA (also known as FUB-AMB, MMB-FUBINACA) were tested for in vivo cannabinoid-like effects to assess their abuse liabilit
As synthetic cannabinoid receptor agonists (SCRA) are gaining popularity globally, clinicians have to understand that intoxication caused by vaping SCRA is not detected by commonly available tests. He confirmed that he had been vaping an electronic cigarette (e-cigarette) earlier that day just before the onset of his symptoms. Metabolic acidosis (1/3, 0/7) and respiratory acidosis (1/3, 0/7), All 10 patients recovered with supportive care, including intubation and ventilation for one case. In 3 cases ADB-BUTINACA was the only substance detected, while in seven other substances of misuse were also detected including other SCRA, opioids, benzodiazepines cocaine and pregabali
The same procedure was then applied to the mice once every day for 5 days. It was considered as coordination disturbance when mice fell from the test apparatus within 2 min. Mice that remained their position on the running apparatus at 10 rpm for at least 2 min were selected for further evaluation.
Table of Conten
High resolution mass spectrometry such as LC-QTOF-MS allows the detection and identification of a broad spectrum of recreational drugs, including new psychoactive substances. A point-of-care drugs of abuse (DOA) test was initially performed on the urine of the patient. He confirmed drinking 750 ml energy drink without any further consumption of food and using an e-cigarette from Gaziantep, Turkey 10 seconds before the onset of his first symptoms. He usually smokes a pack of cigarettes a day and sometimes smokes e-cigarettes. Combined with non-specific, transient symptoms, clinical recognition of SCRA intoxication is challenging .
Data availability
The intensity is plotted against the retention time for both chromatograms, demonstrating the 4f adb presence and elution profiles of nicotine and ADB-BUTINACA in the analysed vape liquid sample. LC-QTOF-MS Chromatograms of Nicotine (Top) and ADB-BUTINACA (Bottom) in the Vape Liquid used by the patient. The LC-QTOF-MS analysis showed that the e-liquid contained nicotine and ADB-BUTINACA (Fig. 1). Because the point-of-care DOA test is generally not able to detect synthetic recreational drug substances, the liquid of the e-cigarette was thereafter screened using liquid chromatography-quadrupole time-of-flight mass spectrometry (LC-QTOF-MS) on the Waters™ Xevo G3 QTOF MS system. After eating a light meal and drinking caffeinated sports drinks at the ER, the nausea complaints of the patient were reduced and the patient was discharged hom